DC voltage (DCV)| Range | Accuracy | Resolution |
| 6V | ± (0.5%+3) | 0.001V |
| 60V | 0.01V |
| 600V | 0.1V |
| 1000V | ± (0.8%+10) | 1V |
AC voltage(DCV)| Range | Accuracy | Resolution |
| 6V | ± (0.8%+3) | 0.001V |
| 60V | 0.01V |
| 600V | 0.1V |
| 750V | ± (1.2%+10) | 1V |
DC Current (DC mA)| Range | Accuracy | Resolution |
| 60mA | ± (1.2%+10) | 10uA |
| 600mA | 100uA |
DC Current (DC uA)| Range | Accuracy | Resolution |
| 600uA | ± (1.2%+10) | 0.1uA |
| 6000uA | 1uA |
AC Current (AC mA)| Range | Accuracy | Resolution |
| 60mA | ± (1.2%+10) | 10uA |
| 600mA | 100uA |
AC Current (AC uA)| Range | Accuracy | Resolution |
| 600uA | ± (1.2%+10) | 0.1uA |
| 6000uA | 1uA |
DC/AC 10A Current (DC/ACA)| Range | Accuracy | Resolution |
| 6A | ± (2.0%+30) | 0.01A |
| 10A | 0.01A |
Resistance (Ω)| Range | Accuracy | Resolution |
| 600Ω | ± (0.8%+5) | 0.1Ω |
| 6kΩ | ± (0.8%+3) | 1Ω |
| 60kΩ | 10Ω |
| 600kΩ | 100Ω |
| 6MΩ | 1kΩ |
| 40MΩ | ± (2.5%+3) | 10kΩ |
Capacitance(C)| Range | Accuracy | Resolution |
| 60nF | ± (3.5%+20) | 10pF |
| 600nF | 100pF |
| 6uF | 1nF |
| 60uF | 10nF |
| 600uF | 100nF |
| 6mF | ± (5%+3) | 11uF |
| 30mF | 10uF |
Frequency measurement:| Range | Accuracy | Resolution |
| 10Hz | ± (0.1%+3) | 0.01Hz |
| 100Hz | 0.1Hz |
| 1kHz | 1Hz |
| 10kHZ | 10Hz |
| 100kHz | 100Hz |
| 1MHz | 1kHz |
| 20MHz | 10kHz |
Temperature measurement (°C/°F) | Range | Accuracy | Resolution |
| (-20-1000 )℃ | ± (1.0%+5) <400℃ ± (1.5%+15)≥400℃ | 1℃ |
| (0-1832 )℉ | ± (0.75%+5) <750℉ ± (1.5%+15)≥750℉ | 1℉ |
Square Wave Output: 50Hz/100Hz/200Hz/300Hz/400Hz/500Hz/600Hz/700Hz/800Hz/ 900Hz/1000Hz/2000HZ/4000HZ/5000HZDuty Cycle: range: 1%~99%;resolution: 0.1%; accuracy: ±(0.1%+2)
Diode: √(DC forward current is 5mA, voltage is 3V)
Continuity: √(no more than 50Ω)
Maximum display: 6000 (3 5/6) bits automatic polarity display
Measurement: double integral A / D conversion
Sampling rate: about 3 times per second
Overrange display: the most significant bit was "0L"
Low voltage display: symbol appears
Working environment: (0 to 40)℃, relative humidity <80%
Power supply: AAA 1.5V battery (Not included)
Volume (size): 142×70×32mm(L×W×H)
Weight: about 200gGood News!The Newest Oscilloscope Multimeter Of MUSTOOL MT8027 will be preorder at the end of June!
A Fully Oscilloscope witth 200MHz Sampling Rate 40MHz Bandwidth + True RMS 6000 counts dispaly digital Multimeter !!!>>More Details Please Click Here<<<